Plant Overview
|
The wastewater treatment facility was constructed in 1979-1980 and became operational in September 1980. The treatment facility was expanded in 1992 to increase the BOD treatment capacity with the addition of a biological filter ahead of the existing rotating biological contactor (RBC) process. A schematic diagram of the Village of Denmark wastewater treatment facility is shown below.
Preliminary treatment includes a rotary fine screen followed by grit removal. A single 40-foot diameter primary clarifier provides primary treatment. A biological filter that reduces the BOD concentration to less than 30 mg/l provides secondary biological treatment. Rotating biological contactors (RBC's) follow the biological filter for nitrification of the wastewater to approximately 1 mg/l NH3-N. Two 30-foot diameter clarifiers provide final clarification followed by cascade aeration. Sludge treatment consists of a 40-foot diameter primary digester, a 40-foot secondary digester, and a 690,000 gallon mixed sludge storage tank for storage prior to land spreading.
Village of Denmark Water Utility »
Village Representatives DNR - Gary Kincaid 662-5136 Village - Erika Sisel/Lew Miller
| Parameter |
Influent |
Effluent |
|
|
mg/l |
Lbs/day |
mg/l |
| Flow, MGD |
- |
- |
.4719 |
| BOD |
803 |
3,064 |
8.33 |
| TSS |
431.75 |
1,532 |
11.5 |
| NH3-N |
10.36 |
- |
.6375 |
| P |
17.22 |
- |
.7416 |
|



Get a full flowchart

|
Sewer Quarterly service charges:
Up to 1" water meter: $25.69 per quarter
Up to 1 1/4" water meter: $41.10 per quarter
Up to 1 1/2" meter $59.09 per quarter
Up to 2" water meter $102.77 per quarter
Up to 3" water meter $231.24 per quarter